Learn More >
or
Close X
It looks like you have JavaScript disabled.
For the best experience, please enable JavaScript.
or
It looks like you have JavaScript disabled and you’re using an outdated browser, which PJM no longer supports.
For the best experience, please enable JavaScript and upgrade to a modern browser.
or
Sign In
Sign In
Tools Sign In
Calendar
Menu
Sign In
about pjm
training
committees
&
groups
planning
markets
&
operations
library
Missing
Missing
Missing
Missing
Home
Three Priorities
Keeping the Lights On
eDART FAQs
Transmission Outage Ticket FAQs
When do I need to verbally notify PJM of transmission outages?
Learning Center
More Questions
Question:
When do I need to verbally notify PJM of transmission outages?
Answer:
Verbal notification is required to PJM:
For any change to a ticket that affects the current or next operating day, including the removal of a ticket from the current or next operating day
For all transmission trippings
At least 30 minutes prior to when switching is ready to begin (takeout/restore)
Upon the actual start and end of an outage ticket (unless otherwise agreed to with the PJM PD, such as if they will see the status change via telemetry)
For any problem entering tickets into eDART
Transmission Outage Ticket FAQs
How do I see the transmission outages that are shown on OASIS, in eDART?
How long does a completed transmission outage remain on the OASIS Transmission Facilities Outage List before it is removed from the listing?
How do I see transmission outages that were previously displayed in the OASIS Transmission Facilities Outage List but have since been completed and removed from this list?
As a transmission owner, must I submit a transmission outage ticket through eDART for trippings?
As a transmission owner, when should I use the “Informational/Hotline Work” checkbox?
As a transmission owner, what should I do if I need to change a transmission outage ticket and it is locked?
As a transmission owner, when should I use the Emergency checkbox?
How are transmission lines arranged in the eDART database?
As a transmission owner, what should I do if I need to put in a ticket but cannot find a certain piece of equipment in eDART?
As a transmission owner, where do I go to find notifications of other companies’ transmission outages?
As a transmission owner, once I acknowledge a transmission outage notification, how can I see it again?
As a transmission owner, what should I do when I receive notification of transmission outages that I don’t want to know about?
As a transmission owner, how can I view all the equipment that I am supposed to receive outage notifications for?
As a transmission equipment owner, which equipment requires eDART transmission outage tickets?
When do I need to verbally notify PJM of transmission outages?
When will I receive verbal notification from PJM about submitted Outage Tickets?
As a transmission owner, can I see a report of generation outages in my transmission zone?
As a transmission owner, how do I access reactive capability information for units in my transmission zone?
As a transmission owner, how do I view the reactive tickets for my zone?
How should I submit an eDART ticket for a job that starts at midnight?
As a transmission owner, what should I put in the Description of Work field?
As a transmission owner, how can I get NERC TADS data to be sent to NERC from eDART?